Keigan's Spec
NGH - 1166 Magic Rd
Job Summary
- Job Id
- keigan-s-spec-20260627013623
- Job Name
- Keigan's Spec
- Builder
- NGH
- Address
- 1166 Magic Rd
- Home Type
- single_story
- Square Footage
- 1800
- Media Panel Location
- Coat Closet
- Rough In Date
- 2026-06-30
- Trim Out Timing
- Package Type
- standard_residential
- Tv Data Locations
- 5
- Demarc Drops
- 2
- Add Ons
- {'extra_tv_data_locations': 1, 'starlink': False, 'camera_count': 0, 'surround_type': 'none', 'extra_data_drops': 0}
Rough-In Material Estimate
| Item | Qty | Unit | Category | Note |
|---|---|---|---|---|
| Leviton 47605-140 panel | 1 | each | rough-in | Standard media panel |
| SC100A nail-on box | 1 | each | rough-in | SAT soffit |
| LV jack ring | 1 | each | rough-in | Upper modem/router location |
| TV/data locations | 5 | location | rough-in | Each has Cat6 + RG-6DS |
| Exterior demarc drops | 2 | drop | rough-in | Each has Cat6 + RG-6DS |
| SAT soffit coax drop | 1 | drop | rough-in | |
| TV/data route | 450 | ft | rough-in route | 5 run(s); requires 1 Cat6, 1 RG-6DS per run. |
| SAT soffit route | 90 | ft | rough-in route | 1 run(s); requires 1 RG-6DS per run. |
| Demarc route | 160 | ft | rough-in route | 2 run(s); requires 2 Cat6, 2 RG-6Q per run. Includes 5 ft exterior service loop per run; leave conductors coiled, taped, protected, and unterminated. |
| Upper modem/router short jumper route | 5 | ft | rough-in route | 1 run(s); requires 1 Cat6, 1 RG-6DS per run. Short data closet connection; prefer leftover cable. |
Pull Efficiency Check
| Group | Status | Message |
|---|---|---|
| TV/data | blocker | TV/data has insufficient complete pull sources for preferred product Cat6 + RG-6 Siamese. |
| SAT soffit | blocker | SAT soffit has insufficient complete pull sources for preferred product RG-6DS. |
| Demarc | blocker | Demarc has insufficient complete pull sources for preferred product 2 Cat6 + 2 RG-6Q Composite. |
| Upper modem/router short jumper | blocker | Upper modem/router short jumper has insufficient complete pull sources for preferred product short Cat6 + RG-6DS leftovers. |
| Cat6 logical conductor capacity | blocker | 775 conductor-ft required; 0 conductor-ft available from configured products. |
| RG-6DS logical conductor capacity | blocker | 545 conductor-ft required; 0 conductor-ft available from configured products. |
| RG-6Q logical conductor capacity | blocker | 320 conductor-ft required; 0 conductor-ft available from configured products. |
Cable Container Use Plan
| Container | Product | Allocated | Remaining | Pull Groups |
|---|
Container Closeout Queue
| Container | Product | Allocated | Planned Remaining | Used For | Prompt |
|---|
Buy/Check Before Rough-In
- Buy/check Cat6: need 775 conductor-ft, configured products have 0.
- Buy/check RG-6DS: need 545 conductor-ft, configured products have 0.
- Buy/check RG-6Q: need 320 conductor-ft, configured products have 0.
- Stage product/source for TV/data: TV/data has insufficient complete pull sources for preferred product Cat6 + RG-6 Siamese.
- Stage product/source for SAT soffit: SAT soffit has insufficient complete pull sources for preferred product RG-6DS.
- Stage product/source for Demarc: Demarc has insufficient complete pull sources for preferred product 2 Cat6 + 2 RG-6Q Composite.
- Stage product/source for Upper modem/router short jumper: Upper modem/router short jumper has insufficient complete pull sources for preferred product short Cat6 + RG-6DS leftovers.
- Verify Leviton 47605-140 panel is on hand.
- Verify SC100A nail-on box and LV jack ring are on hand.
- Do not load standard TV wall plates unless installer used extra boxes.
Trim-Out Materials
| Item | Qty | Unit | Note |
|---|---|---|---|
| 2-port straps | 6 | each | |
| ICC-CAT6JKPK-WH Cat6 keystones | 6 | each | |
| F-type coax keystones | 6 | each | |
| F-type connectors | 14 | each | Includes known coax trim and panel ends; excludes demarc and surround TBD. |
| ICRESDPB3C | 1 | each | |
| SAT coax wall plate, color TBD | 1 | each |
Unresolved Trim-Out Items
- Decora wall plates only if extra boxes were used.
- Demarc termination hardware: none by default.
Critical Trim-Out Items
- ICRESDPB3C for media panel data terminations.
- F-type connectors for coax trim-out locations.
- ICC-CAT6JKPK-WH Cat6 keystones for TV/data and modem/router locations.
Rough-In Closeout Checklist
- Photograph media panel, demarc, SAT soffit, upper modem/router, and all TV/data rough-in locations.
- Label all cables/conductors at both ends by room/location.
- Confirm SAT soffit SC100A box and coax are accessible for trim-out.
- Confirm exterior demarc conductors have service loop, protection, labels, and no termination hardware.
- Record cable containers used and approximate remaining footage.