DropWise MVP

Keigan's Spec

NGH - 1166 Magic Rd

Back To Jobs

Job Summary

Job Id
keigan-s-spec-20260627013623
Job Name
Keigan's Spec
Builder
NGH
Address
1166 Magic Rd
Home Type
single_story
Square Footage
1800
Media Panel Location
Coat Closet
Rough In Date
2026-06-30
Trim Out Timing
Package Type
standard_residential
Tv Data Locations
5
Demarc Drops
2
Add Ons
{'extra_tv_data_locations': 1, 'starlink': False, 'camera_count': 0, 'surround_type': 'none', 'extra_data_drops': 0}

Rough-In Material Estimate

ItemQtyUnitCategoryNote
Leviton 47605-140 panel 1 each rough-in Standard media panel
SC100A nail-on box 1 each rough-in SAT soffit
LV jack ring 1 each rough-in Upper modem/router location
TV/data locations 5 location rough-in Each has Cat6 + RG-6DS
Exterior demarc drops 2 drop rough-in Each has Cat6 + RG-6DS
SAT soffit coax drop 1 drop rough-in
TV/data route 450 ft rough-in route 5 run(s); requires 1 Cat6, 1 RG-6DS per run.
SAT soffit route 90 ft rough-in route 1 run(s); requires 1 RG-6DS per run.
Demarc route 160 ft rough-in route 2 run(s); requires 2 Cat6, 2 RG-6Q per run. Includes 5 ft exterior service loop per run; leave conductors coiled, taped, protected, and unterminated.
Upper modem/router short jumper route 5 ft rough-in route 1 run(s); requires 1 Cat6, 1 RG-6DS per run. Short data closet connection; prefer leftover cable.

Pull Efficiency Check

GroupStatusMessage
TV/data blocker TV/data has insufficient complete pull sources for preferred product Cat6 + RG-6 Siamese.
SAT soffit blocker SAT soffit has insufficient complete pull sources for preferred product RG-6DS.
Demarc blocker Demarc has insufficient complete pull sources for preferred product 2 Cat6 + 2 RG-6Q Composite.
Upper modem/router short jumper blocker Upper modem/router short jumper has insufficient complete pull sources for preferred product short Cat6 + RG-6DS leftovers.
Cat6 logical conductor capacity blocker 775 conductor-ft required; 0 conductor-ft available from configured products.
RG-6DS logical conductor capacity blocker 545 conductor-ft required; 0 conductor-ft available from configured products.
RG-6Q logical conductor capacity blocker 320 conductor-ft required; 0 conductor-ft available from configured products.

Cable Container Use Plan

ContainerProductAllocatedRemainingPull Groups

Container Closeout Queue

ContainerProductAllocatedPlanned RemainingUsed ForPrompt

Buy/Check Before Rough-In

Trim-Out Materials

ItemQtyUnitNote
2-port straps 6 each
ICC-CAT6JKPK-WH Cat6 keystones 6 each
F-type coax keystones 6 each
F-type connectors 14 each Includes known coax trim and panel ends; excludes demarc and surround TBD.
ICRESDPB3C 1 each
SAT coax wall plate, color TBD 1 each

Unresolved Trim-Out Items

  • Decora wall plates only if extra boxes were used.
  • Demarc termination hardware: none by default.

Critical Trim-Out Items

  • ICRESDPB3C for media panel data terminations.
  • F-type connectors for coax trim-out locations.
  • ICC-CAT6JKPK-WH Cat6 keystones for TV/data and modem/router locations.

Rough-In Closeout Checklist